To gain a full understanding of our product please firstly look at the introduction of the features and the functions of our CDCS exam torrent. The page of our product provide the demo and the aim to provide the demo is to let the you understand part of our titles before their purchase and see what form the software is after the you open it. The client can visit the page of our product on the website. So the client can understand our CDCS Quiz torrent well and decide whether to buy our product or not at their wishes. The client can see the forms of the answers and the titles.
EXIN CDCS Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
Latest EXIN CDCS of exam practice questions and answers free download
The price for CDCS learning materials is reasonable, and no matter you are a student or an employee, you can afford the expense. In addition, CDCS exam dumps are edited by professional experts, and therefore the quality can be guaranteed. CDCS exam materials cover most of the knowledge points for the exam, and you can master them through study. In order to let you know the latest information for the exam ,we offer you free update for 365 days after purchasing, and the update version for CDCS Exam Dumps will be sent to you automatically.
EXIN EPI Certified Data Centre Specialist Sample Questions (Q49-Q54):
NEW QUESTION # 49
The temperature in the computer room is being increased from 18°C/64°F to 27°C/81°F.
What is the impact, if any, on the amount of gas required to suppress a fire assuming the gas is a Halocarbon?
Answer: C
Explanation:
With Halocarbon fire suppression systems, as the temperature increases, the amount of gas required for effective suppression decreases. This is because Halocarbon agents are stored as a liquid and discharge as a gas, expanding more at higher temperatures. As a result, less agent is needed at higher room temperatures to achieve the desired concentration for fire suppression.
Detailed Explanation:
Halocarbons rely on specific volumetric concentrations to suppress fires. Higher temperatures cause the agent to expand more rapidly, effectively filling the protected area with less agent needed to reach the required concentration. This is in contrast to some other gases, where temperature changes might not have the same effect on discharge quantities.
EPI Data Center Specialist References:
EPI data center training on fire suppression indicates that understanding the physical properties of agents like Halocarbons is key for correct system sizing. As the temperature rises, the gas expands more readily, thus requiring adjustments in the amount needed for effective coverage.
NEW QUESTION # 50
What is the main reason to install Earth Leakage protection?
Answer: C
Explanation:
Earth Leakage Protection is primarily installed to protect human lives by detecting and disconnecting power when a fault current flows to the ground. This type of protection is essential to avoid electrical shock hazards that could occur when insulation fails, or equipment is improperly grounded.
Detailed Explanation:
Earth leakage currents can occur due to insulation faults or accidental contact with live parts. Earth Leakage Protection systems, such as Residual Current Devices (RCDs), quickly detect these faults and disconnect the circuit to prevent harm to personnel. This is especially crucial in environments like data centers where high-powered equipment is continuously running and any electrical fault can pose significant safety risks.
EPI Data Center Specialist References:
EPI emphasizes that human safety is paramount in data center operations. Proper grounding and leakage protection are fundamental safety measures, and EPI guidelines align with this focus, underscoring the importance of protecting personnel from electrical hazards through appropriate safety systems.
NEW QUESTION # 51
You are allowed to use a calculator for this question. The total power consumption of the ICT equipment in a rack is 6 kW. The equipment is traditional ICT equipment with a Delta-T of approximately 11 °C / 20 °F. Calculate the approximate CFM required to cool the equipment in the rack.
Answer: B
Explanation:
To calculate the cooling airflow requirement for ICT equipment, you can use the formula:
CFM=Power (kW)×3160ΔT(°F) ext{CFM} = rac{ ext{Power (kW)} imes 3160}{Delta T ( ext{°F})}CFM=ΔT(°F)Power (kW)×3160 For equipment consuming 6 kW with a Delta-T of 20°F:
CFM=6×316020=948≈1,000 CFM ext{CFM} = rac{6 imes 3160}{20} = 948 approx 1,000 , ext{CFM}CFM=206×3160=948≈1,000CFM Detailed Explanation:
This formula provides an estimate of the cubic feet per minute (CFM) of air required to cool the equipment based on its power consumption and the temperature difference (Delta-T) between intake and exhaust. The Delta-T represents the cooling effectiveness of the airflow.
EPI Data Center Specialist References:
EPI recommends using this calculation for determining airflow requirements in data centers, ensuring that cooling systems are adequately sized to maintain equipment within safe temperature limits.
NEW QUESTION # 52
The location of a data center is just above the Arctic Circle (North Pole). The outside air temperature is never above 21°C/70°F.
Taking energy efficiency as the highest priority, which cooling system should you recommend?
Answer: C
Explanation:
In locations with consistently cold temperatures, such as above the Arctic Circle, an airside economizer is the most energy-efficient cooling solution. Airside economizers use cool outside air to lower indoor temperatures, reducing or even eliminating the need for mechanical cooling. Given the consistently low temperatures, this method maximizes energy efficiency by leveraging natural cooling.
Detailed Explanation:
Airside economizers are ideal in environments where outside temperatures are consistently low. By drawing in and filtering cold outdoor air, they directly cool the indoor environment, thereby reducing energy consumption significantly compared to traditional air conditioning. This cooling approach aligns with energy efficiency goals by minimizing mechanical cooling demands.
EPI Data Center Specialist References:
EPI recommends the use of airside economizers in cold climates to achieve high energy efficiency, as they allow data centers to capitalize on ambient conditions for cooling, aligning with sustainability and cost-saving practices.
NEW QUESTION # 53
You are installing new copper cabling.
What is the advantage or disadvantage of choosing pre-terminated category 6 or 6A cabling?
Answer: B
Explanation:
Choosing pre-terminated category 6 or 6A cabling provides several advantages, primarily related to time savings and reliability. Since pre-terminated cables are factory tested, they ensure consistent quality and performance, reducing the need for additional testing during installation. This makes installation faster and more efficient, which can significantly reduce labor costs and deployment times.
Detailed Explanation:
Pre-terminated cabling systems are manufactured and tested in controlled environments, which ensures they meet industry standards for performance. This factory testing process minimizes the likelihood of faults, reducing the need for troubleshooting and retesting on-site. Moreover, pre-terminated solutions can help to streamline installations because they eliminate the need for on-site terminations, which can be time-consuming and require skilled labor.
This is especially beneficial for data centers, where rapid deployment and minimizing potential points of failure are critical to maintaining uptime. However, it is important to note that pre-terminated cables require accurate planning, as lengths and connector configurations must be predetermined.
EPI Data Center Specialist References:
According to EPI Data Center Specialist guidelines, pre-terminated cabling is advantageous in data center environments due to reduced installation time and enhanced reliability from factory testing. These attributes align with best practices for efficient data center management, where maintaining performance and minimizing downtime are priorities.
NEW QUESTION # 54
......
The EXIN CDCS certification provides is beneficial to accelerate your career in the tech sector. Today, the EXIN CDCS certification is a fantastic choice to get high-paying jobs and promotions, and to achieve it, you must crack the challenging CDCS Exam. It is critical to prepare with actual EXIN EPI Certified Data Centre Specialist (CDCS) exam questions if you have less time and want to clear the test in a short time. You will fail and waste time and money if you do not prepare with real and updated CDCS Questions.